For the following network to work as lag compensator, the value of R2 would be

This question was previously asked in
ESE Electrical 2015 Paper 1: Official Paper
View all UPSC IES Papers >
  1. R2 ≥ 20 Ω
  2. R2 ≤ 10 Ω
  3. Any value of R2

Answer (Detailed Solution Below)

Option 4 : Any value of R2
Free
ST 1: UPSC ESE (IES) Civil - Building Materials
20 Qs. 40 Marks 24 Mins

Detailed Solution

Download Solution PDF

Lag compensator:

Transfer function:

If it is in the form of , then a < 1

If it is in the form of , then a > b

Maximum phase lag frequency: 

Maximum phase lag: 

ϕis negative

Pole zero plot:

The pole is nearer to the origin.

Filter: It is a low pass filter (LPF)

Effect on the system:

  • Rise time and settling time increases and Bandwidth decreases
  • The transient response becomes slower
  • The steady-state response is improved
  • Stability decreases

 

Application:

The equivalent Laplace transform network for the given network is,

By applying voltage division,

The above system to be lag compensator, β > 1

⇒ R1 > 0

Therefore, at any value of R2 the given system acts as lag compensator.

Latest UPSC IES Updates

Last updated on Jul 2, 2025

-> ESE Mains 2025 exam date has been released. As per the schedule, UPSC IES Mains exam 2025 will be conducted on August 10. 

-> UPSC ESE result 2025 has been released. Candidates can download the ESE prelims result PDF from here.

->  UPSC ESE admit card 2025 for the prelims exam has been released. 

-> The UPSC IES Prelims 2025 will be held on 8th June 2025.

-> The selection process includes a Prelims and a Mains Examination, followed by a Personality Test/Interview.

-> Candidates should attempt the UPSC IES mock tests to increase their efficiency. The UPSC IES previous year papers can be downloaded here.

More Compensators Questions

More Controllers and Compensators Questions

Hot Links: teen patti refer earn teen patti party teen patti yes