Copper losses in a transformer are proportional to:

This question was previously asked in
RRB JE CBT 2 (Electrical Engineering) ReExam Official Paper (Held On: 04 Jun, 2025)
View all RRB JE Papers >
  1. the square of the load current
  2. the square of the frequency
  3. the square of the turns ratio
  4. the square of the voltage 

Answer (Detailed Solution Below)

Option 1 : the square of the load current
Free
General Science for All Railway Exams Mock Test
2.2 Lakh Users
20 Questions 20 Marks 15 Mins

Detailed Solution

Download Solution PDF
Explanation:

Copper Losses in a Transformer

Definition: Copper losses in a transformer refer to the power losses that occur due to the resistance of the winding conductors when current flows through them. These losses are one of the primary contributors to the overall efficiency reduction in a transformer. Copper losses are also known as I2R losses, as they are directly related to the current flowing through the winding and the resistance of the winding material.

Correct Option Analysis:

The correct answer is:

Option 1: Copper losses in a transformer are proportional to the square of the load current.

Explanation:

Copper losses in a transformer are mathematically expressed as:

Power Loss = I2 × R

Where:

  • I is the current flowing through the winding (load current).
  • R is the resistance of the winding conductor.

From the formula above, it is evident that copper losses are proportional to the square of the current (I2). This relationship arises because the power dissipated as heat in the winding resistance is dependent on the square of the current. Therefore, as the load current increases, the copper losses increase quadratically.

In transformers, the load current varies with the load connected to the transformer. As the load current increases, the copper losses increase significantly due to the squared relationship. This is why transformers are typically designed to operate efficiently at their rated load, as excessive copper losses can lead to overheating and reduced efficiency.

Important Considerations:

  • Copper losses are directly related to the winding material's resistance. High-quality materials with low resistivity (such as copper or aluminum) are used to minimize these losses.
  • While copper losses depend on the load current, they do not depend on the voltage, frequency, or turns ratio of the transformer.
  • Reducing the winding resistance by using thicker conductors or reducing the length of the winding can help minimize copper losses.

Additional Information:

To further understand the analysis, let’s evaluate the other options:

Option 2: Copper losses are proportional to the square of the frequency.

This option is incorrect. Copper losses are not dependent on the frequency of the electrical supply. While frequency does affect core losses (hysteresis and eddy current losses), copper losses are solely dependent on the load current and the winding resistance.

Option 3: Copper losses are proportional to the square of the turns ratio.

This option is also incorrect. The turns ratio of a transformer determines the voltage and current transformation between the primary and secondary windings but does not directly influence copper losses. Copper losses depend on the load current flowing through the windings, not on the turns ratio itself.

Option 4: Copper losses are proportional to the square of the voltage.

This option is incorrect. Copper losses are not directly related to the voltage. While the voltage determines the current flowing through the load (based on the load's impedance), copper losses are specifically proportional to the square of the load current, not the voltage.

Conclusion:

Copper losses in a transformer are a critical factor affecting its efficiency and performance. Understanding that these losses are proportional to the square of the load current is essential for designing and operating transformers effectively. By minimizing winding resistance and optimizing the transformer for its rated load, these losses can be reduced, improving the overall efficiency of the transformer.

Latest RRB JE Updates

Last updated on Jul 21, 2025

-> The RRB JE CBT 2 Result 2025 has been released on July 21, 2025 for all RRBs Zones (Ahmedabad, Bengaluru, Jammu-Srinagar, Kolkata, Malda, Mumbai, Ranchi, Secunderabad, and Thiruvananthapuram).

-> RRB JE CBT 2 Scorecard 2025 has been released along with cut off Marks.

-> RRB JE CBT 2 answer key 2025 for June 4 exam has been released at the official website.

-> Check Your Marks via RRB JE CBT 2 Rank Calculator 2025

-> RRB JE CBT 2 admit card 2025 has been released. 

-> RRB JE CBT 2 city intimation slip 2025 for June 4 exam has been released at the official website.

-> RRB JE CBT 2 Cancelled Shift Exam 2025 will be conducted on June 4, 2025 in offline mode. 

-> RRB JE CBT 2 Exam Analysis 2025 is Out, Candidates analysis their exam according to Shift 1 and 2 Questions and Answers.

-> The RRB JE Notification 2024 was released for 7951 vacancies for various posts of Junior Engineer, Depot Material Superintendent, Chemical & Metallurgical Assistant, Chemical Supervisor (Research) and Metallurgical Supervisor (Research). 

-> The selection process includes CBT 1, CBT 2, and Document Verification & Medical Test.

-> The candidates who will be selected will get an approximate salary range between Rs. 13,500 to Rs. 38,425.

-> Attempt RRB JE Free Current Affairs Mock Test here

-> Enhance your preparation with the RRB JE Previous Year Papers

Get Free Access Now
Hot Links: teen patti master list teen patti game online all teen patti game